siemens convolution kernels Search Results


90
Siemens AG siemens convolution kernels
Table of acquisition parameters for each scanner investigated. The second column shows the primary AEC settings for all scanners. SD is the primary AEC parameter on Toshiba scanners, which represents the standard deviation of CT numbers (i.e. noise). QRM, which stands for Quality Reference mAs, is the primary AEC parameter for Siemens scanners and represents the effective mAs for a reference patient size. NI, which stands for Noise Index, is the primary AEC parameter for GE scanners and represents the target noise value in the acquired image. Iterative based reconstruction is noted by AIDR 3D for the Toshiba scanner and SS30 (ASIR) setting for the GE scanners in the <t> convolution </t> kernel column.
Siemens Convolution Kernels, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/siemens+convolution+kernels/pmc04632971-196-18-18?v=Siemens+AG
Average 90 stars, based on 1 article reviews
siemens convolution kernels - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Siemens AG smooth convolution kernel
Table of acquisition parameters for each scanner investigated. The second column shows the primary AEC settings for all scanners. SD is the primary AEC parameter on Toshiba scanners, which represents the standard deviation of CT numbers (i.e. noise). QRM, which stands for Quality Reference mAs, is the primary AEC parameter for Siemens scanners and represents the effective mAs for a reference patient size. NI, which stands for Noise Index, is the primary AEC parameter for GE scanners and represents the target noise value in the acquired image. Iterative based reconstruction is noted by AIDR 3D for the Toshiba scanner and SS30 (ASIR) setting for the GE scanners in the <t> convolution </t> kernel column.
Smooth Convolution Kernel, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/siemens+convolution+kernels/pmc11669717-92-8-13?v=Siemens+AG
Average 90 stars, based on 1 article reviews
smooth convolution kernel - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Siemens AG convolution kernel employing fbp and iterative reconstruction (ir) safire
Table of acquisition parameters for each scanner investigated. The second column shows the primary AEC settings for all scanners. SD is the primary AEC parameter on Toshiba scanners, which represents the standard deviation of CT numbers (i.e. noise). QRM, which stands for Quality Reference mAs, is the primary AEC parameter for Siemens scanners and represents the effective mAs for a reference patient size. NI, which stands for Noise Index, is the primary AEC parameter for GE scanners and represents the target noise value in the acquired image. Iterative based reconstruction is noted by AIDR 3D for the Toshiba scanner and SS30 (ASIR) setting for the GE scanners in the <t> convolution </t> kernel column.
Convolution Kernel Employing Fbp And Iterative Reconstruction (Ir) Safire, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/siemens+convolution+kernels/pmc04756736-53-31-39?v=Siemens+AG
Average 90 stars, based on 1 article reviews
convolution kernel employing fbp and iterative reconstruction (ir) safire - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Siemens AG quantitative reconstruction kernel qr40
Table of acquisition parameters for each scanner investigated. The second column shows the primary AEC settings for all scanners. SD is the primary AEC parameter on Toshiba scanners, which represents the standard deviation of CT numbers (i.e. noise). QRM, which stands for Quality Reference mAs, is the primary AEC parameter for Siemens scanners and represents the effective mAs for a reference patient size. NI, which stands for Noise Index, is the primary AEC parameter for GE scanners and represents the target noise value in the acquired image. Iterative based reconstruction is noted by AIDR 3D for the Toshiba scanner and SS30 (ASIR) setting for the GE scanners in the <t> convolution </t> kernel column.
Quantitative Reconstruction Kernel Qr40, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/siemens+convolution+kernels/pm39133989-54-14-18?v=Siemens+AG
Average 90 stars, based on 1 article reviews
quantitative reconstruction kernel qr40 - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Siemens AG convolution kernel siemens br44
Table of acquisition parameters for each scanner investigated. The second column shows the primary AEC settings for all scanners. SD is the primary AEC parameter on Toshiba scanners, which represents the standard deviation of CT numbers (i.e. noise). QRM, which stands for Quality Reference mAs, is the primary AEC parameter for Siemens scanners and represents the effective mAs for a reference patient size. NI, which stands for Noise Index, is the primary AEC parameter for GE scanners and represents the target noise value in the acquired image. Iterative based reconstruction is noted by AIDR 3D for the Toshiba scanner and SS30 (ASIR) setting for the GE scanners in the <t> convolution </t> kernel column.
Convolution Kernel Siemens Br44, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/siemens+convolution+kernels/pm31484865-45-18-20?v=Siemens+AG
Average 90 stars, based on 1 article reviews
convolution kernel siemens br44 - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Siemens AG vascular convolution kernel bv44
Table of acquisition parameters for each scanner investigated. The second column shows the primary AEC settings for all scanners. SD is the primary AEC parameter on Toshiba scanners, which represents the standard deviation of CT numbers (i.e. noise). QRM, which stands for Quality Reference mAs, is the primary AEC parameter for Siemens scanners and represents the effective mAs for a reference patient size. NI, which stands for Noise Index, is the primary AEC parameter for GE scanners and represents the target noise value in the acquired image. Iterative based reconstruction is noted by AIDR 3D for the Toshiba scanner and SS30 (ASIR) setting for the GE scanners in the <t> convolution </t> kernel column.
Vascular Convolution Kernel Bv44, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/siemens+convolution+kernels/10__3174_slash_ajnr__a5372-52-21-30?v=Siemens+AG
Average 90 stars, based on 1 article reviews
vascular convolution kernel bv44 - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Siemens AG convolution kernel with iterative reconstruction i30; iris
Table of acquisition parameters for each scanner investigated. The second column shows the primary AEC settings for all scanners. SD is the primary AEC parameter on Toshiba scanners, which represents the standard deviation of CT numbers (i.e. noise). QRM, which stands for Quality Reference mAs, is the primary AEC parameter for Siemens scanners and represents the effective mAs for a reference patient size. NI, which stands for Noise Index, is the primary AEC parameter for GE scanners and represents the target noise value in the acquired image. Iterative based reconstruction is noted by AIDR 3D for the Toshiba scanner and SS30 (ASIR) setting for the GE scanners in the <t> convolution </t> kernel column.
Convolution Kernel With Iterative Reconstruction I30; Iris, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/siemens+convolution+kernels/pmc10510986-18-33-36?v=Siemens+AG
Average 90 stars, based on 1 article reviews
convolution kernel with iterative reconstruction i30; iris - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Siemens AG sharp convolution kernel siemens b46f
Table of acquisition parameters for each scanner investigated. The second column shows the primary AEC settings for all scanners. SD is the primary AEC parameter on Toshiba scanners, which represents the standard deviation of CT numbers (i.e. noise). QRM, which stands for Quality Reference mAs, is the primary AEC parameter for Siemens scanners and represents the effective mAs for a reference patient size. NI, which stands for Noise Index, is the primary AEC parameter for GE scanners and represents the target noise value in the acquired image. Iterative based reconstruction is noted by AIDR 3D for the Toshiba scanner and SS30 (ASIR) setting for the GE scanners in the <t> convolution </t> kernel column.
Sharp Convolution Kernel Siemens B46f, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/siemens+convolution+kernels/pmc01914269-41-6-9?v=Siemens+AG
Average 90 stars, based on 1 article reviews
sharp convolution kernel siemens b46f - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Siemens AG convolution kernel br68
Table of acquisition parameters for each scanner investigated. The second column shows the primary AEC settings for all scanners. SD is the primary AEC parameter on Toshiba scanners, which represents the standard deviation of CT numbers (i.e. noise). QRM, which stands for Quality Reference mAs, is the primary AEC parameter for Siemens scanners and represents the effective mAs for a reference patient size. NI, which stands for Noise Index, is the primary AEC parameter for GE scanners and represents the target noise value in the acquired image. Iterative based reconstruction is noted by AIDR 3D for the Toshiba scanner and SS30 (ASIR) setting for the GE scanners in the <t> convolution </t> kernel column.
Convolution Kernel Br68, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/siemens+convolution+kernels/pm37217553-67-3-17?v=Siemens+AG
Average 90 stars, based on 1 article reviews
convolution kernel br68 - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Siemens AG sharp convolution kernel siemens bv49
Table of acquisition parameters for each scanner investigated. The second column shows the primary AEC settings for all scanners. SD is the primary AEC parameter on Toshiba scanners, which represents the standard deviation of CT numbers (i.e. noise). QRM, which stands for Quality Reference mAs, is the primary AEC parameter for Siemens scanners and represents the effective mAs for a reference patient size. NI, which stands for Noise Index, is the primary AEC parameter for GE scanners and represents the target noise value in the acquired image. Iterative based reconstruction is noted by AIDR 3D for the Toshiba scanner and SS30 (ASIR) setting for the GE scanners in the <t> convolution </t> kernel column.
Sharp Convolution Kernel Siemens Bv49, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/siemens+convolution+kernels/pmc08921129-54-14-17?v=Siemens+AG
Average 90 stars, based on 1 article reviews
sharp convolution kernel siemens bv49 - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Siemens AG convolution kernels siemens bv40d
Table of acquisition parameters for each scanner investigated. The second column shows the primary AEC settings for all scanners. SD is the primary AEC parameter on Toshiba scanners, which represents the standard deviation of CT numbers (i.e. noise). QRM, which stands for Quality Reference mAs, is the primary AEC parameter for Siemens scanners and represents the effective mAs for a reference patient size. NI, which stands for Noise Index, is the primary AEC parameter for GE scanners and represents the target noise value in the acquired image. Iterative based reconstruction is noted by AIDR 3D for the Toshiba scanner and SS30 (ASIR) setting for the GE scanners in the <t> convolution </t> kernel column.
Convolution Kernels Siemens Bv40d, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/siemens+convolution+kernels/pmc08692106__mmc1-94-46-48?v=Siemens+AG
Average 90 stars, based on 1 article reviews
convolution kernels siemens bv40d - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Siemens AG workstation medium sharp convolution kernel
Table of acquisition parameters for each scanner investigated. The second column shows the primary AEC settings for all scanners. SD is the primary AEC parameter on Toshiba scanners, which represents the standard deviation of CT numbers (i.e. noise). QRM, which stands for Quality Reference mAs, is the primary AEC parameter for Siemens scanners and represents the effective mAs for a reference patient size. NI, which stands for Noise Index, is the primary AEC parameter for GE scanners and represents the target noise value in the acquired image. Iterative based reconstruction is noted by AIDR 3D for the Toshiba scanner and SS30 (ASIR) setting for the GE scanners in the <t> convolution </t> kernel column.
Workstation Medium Sharp Convolution Kernel, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/siemens+convolution+kernels/pm28066888-107-33-32?v=Siemens+AG
Average 90 stars, based on 1 article reviews
workstation medium sharp convolution kernel - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

Image Search Results


Table of acquisition parameters for each scanner investigated. The second column shows the primary AEC settings for all scanners. SD is the primary AEC parameter on Toshiba scanners, which represents the standard deviation of CT numbers (i.e. noise). QRM, which stands for Quality Reference mAs, is the primary AEC parameter for Siemens scanners and represents the effective mAs for a reference patient size. NI, which stands for Noise Index, is the primary AEC parameter for GE scanners and represents the target noise value in the acquired image. Iterative based reconstruction is noted by AIDR 3D for the Toshiba scanner and SS30 (ASIR) setting for the GE scanners in the  convolution  kernel column.

Journal: Physics in medicine and biology

Article Title: A cross-platform survey of CT image quality and dose from routine abdomen protocols and a method to systematically standardize image quality

doi: 10.1088/0031-9155/60/21/8381

Figure Lengend Snippet: Table of acquisition parameters for each scanner investigated. The second column shows the primary AEC settings for all scanners. SD is the primary AEC parameter on Toshiba scanners, which represents the standard deviation of CT numbers (i.e. noise). QRM, which stands for Quality Reference mAs, is the primary AEC parameter for Siemens scanners and represents the effective mAs for a reference patient size. NI, which stands for Noise Index, is the primary AEC parameter for GE scanners and represents the target noise value in the acquired image. Iterative based reconstruction is noted by AIDR 3D for the Toshiba scanner and SS30 (ASIR) setting for the GE scanners in the convolution kernel column.

Article Snippet: Also included spatial frequencies that yielded modulation transfer function values of 50%, 10%, and 2% for three different Siemens convolution kernels.

Techniques: Standard Deviation

Plot of the MTF curves measured on all of the investigated scanners (each manufacturer plotted with a different colour: GE—blue, Siemens—red, and Toshiba—green), along with MTF curves measured using a range of Siemens convolution kernels (dashed black lines), where B10 is the smoothest body kernel and B50 is a very sharp body kernel.

Journal: Physics in medicine and biology

Article Title: A cross-platform survey of CT image quality and dose from routine abdomen protocols and a method to systematically standardize image quality

doi: 10.1088/0031-9155/60/21/8381

Figure Lengend Snippet: Plot of the MTF curves measured on all of the investigated scanners (each manufacturer plotted with a different colour: GE—blue, Siemens—red, and Toshiba—green), along with MTF curves measured using a range of Siemens convolution kernels (dashed black lines), where B10 is the smoothest body kernel and B50 is a very sharp body kernel.

Article Snippet: Also included spatial frequencies that yielded modulation transfer function values of 50%, 10%, and 2% for three different Siemens convolution kernels.

Techniques:

Statistics of spatial frequencies that yielded modulation transfer function values of 50%, 10%, and 2%. Also included spatial frequencies that yielded modulation transfer function values of 50%, 10%, and 2% for three different  Siemens convolution kernels.

Journal: Physics in medicine and biology

Article Title: A cross-platform survey of CT image quality and dose from routine abdomen protocols and a method to systematically standardize image quality

doi: 10.1088/0031-9155/60/21/8381

Figure Lengend Snippet: Statistics of spatial frequencies that yielded modulation transfer function values of 50%, 10%, and 2%. Also included spatial frequencies that yielded modulation transfer function values of 50%, 10%, and 2% for three different Siemens convolution kernels.

Article Snippet: Also included spatial frequencies that yielded modulation transfer function values of 50%, 10%, and 2% for three different Siemens convolution kernels.

Techniques: